Omega-engineering OME-A826PG Manual de usuario Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 60
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
OME-A-826PG Software Manual [Win 95/98/NT]
1.2 Range Configuration Code
The AD converter of the OME-A-826PG is 16 bits under all
configuration code. If the analog input range is configured to ±5V range, the
resolution of one bit is equal to 2.44 mV. If the analog input range is configured to
±2.5V range, the resolution will be 1.22 mV. If the analog input signal is about
1 V, use configuration 0/1/2 (for OME-A-826PG), it will get nearly the same result
except resolution. So choose the correct configuration code can achieve
the most high precision measurement.
OME-A-826PG Input Signal Range Configuration Code Table
Bipolar/Unipolar
Input Signal Range Configuration Code
Bipolar
± 10V
0
Bipolar
± 5V
1
Bipolar
± 2.5V
2
Bipolar
± 1.25V
3
Date: Aug-15-2000 Ver: 2.2 Page 6
Vista de pagina 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 59 60

Comentarios a estos manuales

Sin comentarios