4.3.1 Main Control Window Pull-Down Operations
Below are the operations that are available in the Pull-Down Menus of the DAQ
Central Main Control Window.
Figure 4-5. File Menu
Open Configuration Opens Device Configuration settings from a saved file
Save Configuration As Saves current Device Configuration settings to a new file name
These settings files contain all of the data that is found in the Device
Configuration window.
Figure 4-6. Device Menu
Detect Devices Detects available OM-DAQ-USB-2401 devices which are currently
connected to the computer through the USB.
Configuration Same function as Configuration button
.
Accesses the device
Configuration window to configure ‘Channels’ settings, ‘Triggers’
settings, and ‘Data’ settings.
Start Acquisition Same function as Start button
.
. Initiates data acquisition for
the highlighted device. Even if a Start Trigger is set, this must be
selected to Arm the device.
Stop Acquisition Same function as Stop button . Stops data acquisition for the
highlighted device. If a Stop Trigger is set, this will cancel the trigger.